Micro Flow Through Electrodes

LC, HPLC, FIA, Biotechnology

Micro Flow Through pH Monitor
Micro Flow Through pO2 and pCO2 Electrodes
Micro flow through ION Electrodes
High Performance Flow Through Conductivity Monitor
Autoclavable pH FLow through Electrodes

Go back to Main Product Search



Micro Flow Through pH Monitor

Low dead volume system designed specifically for chromafocusing, HPLC bioreactor, & organ perfusion. Features *Low dead Volume - Flow pH electrode has an internal volume of less than 50 microliters. *Attaches directly to LC or HPLC Plumbing - The probe uses 1/8 inch fluoropolymer tubing terminated with 1/4 - 28 end fitting which are directly adaptable to LC and HPLC systems. *Use with LAB pH meter - The micro flow pH electrode plugs directly into any standard laboratory pH meter. *Continuous pH recording - The flow through pH probe can be hooked up through a pH meter to a strip chart recorder for continuous pH monitoring. Ordering Information Model FTPH-1A Micro flow through pH system includes pH electrode and micro flow cell Return Top of Page Get Additional Information on Product How to Order

Micro Flow Through pO2 and pCO2 Electrodes

Features *Use in Bioreactor, Cell Culture, and Organ Perfusion - pO2 system low volume (80 microliter) is ideally suited for in line monitoring of bioreactors, organ perfusion and cell culture. pCO2 volume is 100 microliter. *Adapts to silastic tubing End fittings on pO2 & pCO2 probes attach directly to standard silastic tubing. *Use with your pH meter pO2 & pCO2 probes plug directly into your pH meter. *Continuous pO2 & CO2 monitoring using strip chart recorder. Ordering Information Model DO-166FT flow through pO2 Probe Model GS-136COFT micro flow through CO2 Probe Return Top of Page Get Additional Information on Product How to Order

Micro Flow Through Conductivity Monitor

Designed for *Salt gradient elution of proteins *Column LC *Ion chromatography Features *Collect protein fractions on basis of conductivity - increase accuracy and reproducibility of LC protein separations. *Monitor anions and cations in ion chromatography Low dead volume. Conductivity flow cell has an internal volume of less than 80 microliters. *Attaches directly to LC or HPLC plumbing using 1/4 28 fittings. Continuous conductivity recording. Conductivity monitor attaches directly to strip chart recorder for recording conductivity profile. Can also be used with your pH meter. Ordering Information Model COND-158B conductivity monitor complete with flow through cell Return Top of Page Get Additional Information on Product How to Order

Micro Flow Through Ion Probes --K, Na, Cl

Useful for FIA, HPLC, Biotechnology -- Ion electrodes are ideally suited for critical analysis in FIA, chromatography, and biotechnology. *High Sensitivity - K, Na, Cl probes will measure down to 10 -6 Molar (less than 1 ppm). *Low Internal Volume - less than 50 microliters *Combination Format - electrodes include internal reference and can be used with any pH/millivolt meter Orfering Information Model ISM-146KFT potassium probe, ISM-146NAFT sodium probe, ISM-146CLFT chloride probe, each probe Return Top of Page Get Additional Information on Product How to Order

High Performance Micro Flow Through Conductivity Monitor

An indispensable tool for Ion Exchange separations of proteins or ION chromotography Monitor uses ultra stable electronics including electronic zero suppression and automatic temprature control combined with ultra low volume flow cell You can now optimize the salt gradient separation of proteins by continuously monitoring the conductivity of your ion exchange buffer during your run. Build your own modular ion chromatography system Features *Indispensable tool for LC gradient elution of proteins. The conductivity monitor is ideally suited for continuous monitoring of salt gradients in Ion exchange, reverse phase, hydrophobic interaction and hydroxylapetite separations. *Ultrastable solid state electronics. The conductivity monitor uses the latest state of the art integrated circuitry, giving baseline stability, signal to noise ratio and overall performance comparable to units costing many times as much. *Electronic zero suppression. The conductivity monitor can be adjusted from 0 to 200% zero suppression using a panel mounted precision 10 turn potentiometer. *Broad conductivity ranges. The conductivity monitor has 3 front panel selectable conductivity ranges: 0 to 50, 0 to 500, and 0 to 5000 micromhos/cm. *Low volume flow cell. The conductivity cell has an internal volume of less than 20 microliters. *Positive temperature control. The conductivity monitor incorporates a thermister in the flow cell for positive temperature compensation. *Ideal for low cost methods development. The conductivity monitor is ideal for low cost chromatography methods development for a wide variety of samples using different columns. *Compatible with all popular protein chromatography systems. Directly adaptable to Pharmacia r, Biorad r, and Waters r, protein separation systems. Specify manufacturer and model number on purchase order to get exact compatibility. *High Performance at low cost. The Acu I monitor has features such as zero suppression, which even some of the much more expensive units don't have, at a fraction of the cost. Application Areas *Eliminate guesswork in protein separations. Determine exact eluent compositions at the point that each protein elutes form the LC column. *Optimize Desalting. Determine optimal cutoff point of separation of salt from protein in gel filtration. *Minimize regeneration time of ion exchange columns. Minimize the time to equilibrate an ion exchange column after a separation completion. *Verify column packing efficiency. Determine LC column packing efficiency before proceeding with separation run. ORDERING INFORMATION Model ICM-180 conductivity monitor, including 20 microliter flow cell, 3 conductivity ranges from 0 to 5000 micromho/cm, electronic zero suppression, and 0 to 1 volt full scale recorder output. Model ICM-180DM digital display for direct digital readout of conductivity. Attaches directly to Model ICM-180 conductivity monitor. Price... Return Top of Page Get Additional Information on Product How to Order

Autoclavable pH Flow Through Electrode Cells

The LAZAR Flow Through Cell is available in a 6000 ul, a 800 ul semi-micro or 200 ul micro cell. This electrode system is designed for continuous pH measurements in the laboratory where low volume is required. The cell design makes it suitable for a variety of low flow applications which require micro sampling. The flow through cells are available in borosilicate glass, 316L Stainless Steel and Ultem sterilizable plastic with silicone O-rings. These cells are designed to be steam sterilized in an autoclave with the electrode installed. ORDERING INFORMATION ~NOTE Order flow cell and electrode separately. Specify type of electrode cable and electrode connector when ordering. FLOW CELLS *6000 Microliter Flow Cell for 1071001: 1071001 - Flow cell, without electrode, constructed of borosilicate glass. Cell volume 6000 microliters. 7mm O.D. x 5mm I.D. 7mm inlet and outlet tube connections. Temperature range -5 degrees to 130 degrees C. (Order electrode separately). 1051006 - Flow cell, without electrode, constructed of 316L Stainless Steel, cell volume 6000 microliters. 6.3mm O.D. x 5mm I.D. 6mm tube inlet and outlet connections. Temperature range -5 degrees to 130 degrees C. (Order electrode separately). 1001005 - Flow cell, without electrode, constructed of sterilizable Ultem plastic. Cell volume 6000 microliters. 6.3 mm O.D. x 5mm I.D. 6mm tube inlet and outlet connections. Temperature range -5 degrees to 130 degrees C. (Order electrode separately). ~Note: Larger cell volumes are available upon request. *800 microliter Semi-Micro Flow Cell for 1071003: 1071003 - Semi-Micro flow cell, without electrode. Constructed of borosilicate glass. Cell volume 800 microliters. 3mm O.D. x 1.5mm I.D. inlet and outlet tube connections. (Order electrode separately). *200 microliter Micro Flow Cell: 1001007 - Micro flow cell, without electrode, constructed of sterilizable Ultem plastic. Cell volume 200 microliter. 3mm O.D. x 1.5mm I.D., 3mm tube inlet and outlet connections. Temperature range -5 degrees to 140 degrees C. (Order electrode separately). 1051007 - Micro flow cell constructed of 316L Stainless Steel. Cell volume 200 microliters. 3mm O.D. x 1.5mm I.D. 3mm tube inlet and outlet connections. Temperature range -5 degrees to 140 degrees C. (Order electrode separately). ELECTRODES *6000 Microliter Flow Cell Electrodes for 1071001: S773791-DL - Autoclavable, sealed, combination double junction, pH electrode. Sealed Ag/AgCl reference requires no refilling. Internal electrolyte bridge 4M KCI saturated with AgCl; outer reference electrolyte bridge 1M KNO3; annular ceramic reference junction; low profile pH bulb; detachable lead. Dimensions: 12mm O.D. x 80mm length, 0 to 13 pH, -5 degrees to 135 degrees C. A773791-DL - Autoclavable, refillable, combination, double junction, pH electrode. Refillable outer reference electrolyte bridge; sealed Ag/AgCl internal electrolyte bridge; annular ceramic reference junction; low profile pH bulb; detachable lead. Dimensions: 12mm O.D. x 80mm length, 0 to 13 pH, -5degrees to 135 degrees C. *6000 Microliter Flow Cell Electrodes for 1001005 & 1051006: U773791 - Autoclavable, sealed, combination, double junction, pH electrode. Sealed Ag/AgCl reference requires no refilling. Internal electrolyte bridge 4M KCI saturated with AgCl; outer reference electrolyte bridge 1M KNO3; annular ceramic reference junction; low profile pH bulb; detachable lead. Dimensions: 20mm O.D. x 127mm length, 0 to 13 pH, -5degrees to 135 degrees C. *800 microliter Semi-Micro Flow Cell Electrodes for 1071003: S743791-DL - Autoclavable, sealed, combination, double junction, pH electrode. Sealed Ag/AgCl reference requires no refilling. Internal electrolyte bridge 4M KCI saturated with AgCl; outer reference electrolyte bridge 1M KNO3; annular ceramic reference junction; low profile pH bulb; detachable lead. Dimensions: 12mm O.D. x 80mm length, 0 to 13 pH, -5degrees to 135 degrees C. A743791-DL - Autoclavable, refillable, combination, double junction, pH electrode. Refillable outer reference electrolyte bridge; sealed Ag/AgCl internal electrolyte bridge; annular ceramic reference junction; low profile pH bulb; detachable lead. Dimensions: 12mm O.D. x 80mm length, 0 to 13 pH, -5degrees to 135 degrees C. *200 microliter Micro Flow Cell Electrodes for 1001007 & 1051007: U743791 - Autoclavable, sealed, combination, double junction, pH electrode. Sealed Ag/AgCl reference requires no refilling. Internal electrolyte bridge 4M KCI saturated with Ag/AgCl; outer reference electrolyte bridge 1M KNO3; annular ceramic reference junction; low profile pH bulb; detachable lead. Dimensions: 20mm O.D. x 127mm length, 4mm O.D. electrode tip, 0 to 13 pH, -5 degrees to 135 degrees C. Return Top of Page Get Additional Information on Product How to Order